VHR
9200 battery charging and discharging test system
Release time:2017-02-23 14:49:48 | viewed:

9200 battery testing system is mainly used for EV/HEV battery charging and discharging test. There are two types of DC power module that can be configured in the system: 4912 and 4960. The module 4912 is low-voltage and high-current type, while the module 4960 is high-voltage and low-current type.


Ø Touch screen interface: 

  Through the touch screen, you can be very convenient to control the work mode and monitor the charge and discharge voltage, current, power, etc.


Ø Energy recovery:

When do the battery discharge test, part of the electricity power that the battery output will recovery to power grid via the power module, environmentally friendly and economical.


                


Ø Battery emulation:

  A battery emulation mode is provided for testing such as battery chargers, EV on-board DC-DC convertors and regenerative system. Shorter test times are possible by using a fully programmable simulated battery in lieu of preparing actual batteries for test.

 

Model

4912

4960

Programming Capability



Operating States

Standby, Charge, Discharge, Battery Emulation

Standby, Charge, Discharge, Battery Emulation

Charge/Discharge Modes

CV,CC,CP,CR

CV,CC,CP,CR

Charging Envelope

0-120 V, 7 kW, 200 A

0-600 V, 8 kW, 40 A

Discharging Envelope

4-120 V, 12 kW, 200 A

20-600 V, 12 kW, 40 A

Parallel Control

Synchronous control for up to 12 channels for up to 144 kW

Synchronous control for up to 12 channels for up to 144 kW

Macro Test Profiles


   Development Source

Labview, Touch-Panel, or import from Excel

Labview, Touch-Panel, or import from Excel

   Maximum Steps

1000

1000

   Minimum Time Delay

5ms

50μs

   Current Reverse Time

10ms

<10ms

   Settings Change Time

1ms

<5ms

Slew Rate Settings

0 - 1200 V/S,

0 - 20,000 A/S

0.165 - 600,000 V/S

0.011 - 40,000 A/S

Programming


Voltage



    Range

0-120V

0-600 V

    Accuracy

0.1%+0.1%

0.1% + 0.1%

    Resolution

0.01%

0.01%

Current



    Range

±200A

±40 A

    Accuracy

0.2%+0.2%

0.2% + 0.2%

    Resolution

0.01%

0.01%

Power



    Range

±12kW

±12 kW

    Accuracy

0.4%+0.4%

0.4% + 0.4%

    Resolution

0.01%

0.01%

Resistance



    Range

0-1kW

0 -100Ω

    Accuracy

<1mW;<1W


    Resolution

6%;2%


Test Measurement (4-Wire)


Voltage, DC Average



    Range

0-120V

0-600V

    Accuracy

0.05%+0.05%

0.05% + 0.05%

    Resolution

0.01%

0.01%

Current, DC Average, Amp-Hr



    Range

0 - 200A

0-40A

    Accuracy

0.1% + 0.1%

0.1% + 0.1%

    Resolution

0.01%

0.01%

Power, Watt-Hr



    Range

± 12 kW

± 12 kW

    Accuracy

0.4% + 0.4%

0.4% + 0.4%

    Resolution

0.01%

0.01%

Time



    Range

1 mS - 1 yr

1 mS - 1 yr

    Accuracy

0.10%

0.10%

    Resolution

0.002%

0.002%

Control


Local User Interface

Touch-Panel with graphic meters & controls plus Macro development/execution screens

Ext. System Communication

LAN (Ethernet)

Analog Current Monitor

0 to +10V charge/0 to -10V discharge

Analog Voltage Monitor

0 to +10 V full scale voltage

Safety


Channel Internal Protection

Over Voltage (OV) / Under-Voltage (UV), Over-Current (OC), Over-Power (OP), Internal Over-Temperature (OT)

 


 
 In the previous:NHR power automatic testing system——5000 Series